CONSIDERATIONS TO KNOW ABOUT PE AUTOSAMPLER

Considerations To Know About pe autosampler

Considerations To Know About pe autosampler

Blog Article

Mixing by aspiration—mixing of sample by aspiration in lieu of shaking guarantees homogeneity in the sample and maintains cell viability

The CytKick Max Autosample features a Raise method that allows speedier sample processing, along with passive cooling for many plates/racks. A CytKick Max Accessory Package is provided which contains 4 accent plates: two cooling plates and two tube adaptors, in addition to a Max dongle key. A computer just isn't involved with the autosampler given that just one is supplied with the cytometer.

To forestall probe crashes, which can involve costly probe substitute, the CytKick Max Autosampler instantly performs a probe self-calibration to help you assure reliable positioning of your probe in just every well. The self-calibration verifies correct function of the probe, reduces variability in probe positioning as time passes to prevent failures throughout plate operates, and can help make improvements to dependability in excess of the life of the system.

Unlike other plate loaders that blend samples by shaking, which may not make sure homogeneity of the sample, the CytKick Max Autosampler mixes samples by aspiration and stirring, enabling uniform mixing though preserving sample viability and leading to steady information with CVs less than ten% across the plate. The CytKick Max Autosampler also has a delicate combine mode for fragile mobile lines.

The autosampler’s indicator lights and warning systems are actually made to make certain a user who's got walked far from the procedure can easily begin to see the program position continually.

To maintain process versatility, the handbook sample probe is always available even when the loader is current, and switching concerning tubes and plates is detected through software and isn't going to require added person intervention.

The CytKick Max Autosampler was perkin elmer autosampler intended to minimize program down time. Automatic sampling devices are sometimes plagued by clogging or probe crashes. The Intelligent Probe, that has a two hundred-micron diameter that's much larger than most probes accessible while in the field, minimizes situations of clogging.

The intuitive application will allow fast Finding out and facts analysis. For instance, a heat map look at lets immediate screening and affirmation of samples while the instrument is acquiring information.

Straightforward transition—no disassembly, no added QC, no reboot essential for conversion involving plates and tubes

The CytKick Max Autosampler has two selections for processing samples in a high-throughput atmosphere: higher-throughput mode and boost manner.

Self-calibration of your probe also will allow the autosampler to generally be easily moved, so it can be shared involving various devices.

The instrument style and software program had been produced with buyer ease-of-use in your mind. The CytKick Max Autosampler has fluidic bottles with sensors that notify the user when the fluids should be replaced.

Autocleaning of autosampler is done during the instrument shutdown system thus no more user steps are expected to keep up system.

Putting together an experiment Together with the Attune NxT cytometric software program is straightforward. Using a plate structure check out, users can generate compensation wells, outline instrument configurations, and discover samples.

Report this page